CMS1200G Contec 12 Channel ECG Machine Cms1200g
₹48,000
Seller : VD BIO MEDISYSTEMS
Specification
- type
- Non Portable
- brand
- Contec
- weight
- 2 Kg
- warranty
- 1 Year
- dimension
- 40*25*40cm
- usage type
- Resting ECG
- accessories
- User Manual And Warranty Card
- paper width
- 210 mm
- connectivity
- USB
- display type
- Touchscreen LCD
- machine type
- Digital
- power source
- Rechargeable Battery
- interpretation
- With Interpretation
- operating mode
- Automatic
- packaging type
- Box
- recording type
- Thermal Printing
- digital display
- Yes
- internal memory
- Up to 100 ECGs
- model name number
- CMS1200G
- usage application
- Hospital
- number of channels
- 12 Channels
- sterile non sterile
- Non Sterile
MOQ: 1
Add Quantity
Description
General Features;Sync Collection for 12-Lead ECG, Adopt Digital Signal Processing Technology and Get High-Quality ECG Waveform via Power Frequency Filter, Baseline Filter and MG Filter of ECG Signal Display Of 3/6/12-Lead ECG, Print Mode, Sensitivity, Paper Speed and Filter State etc. On One Screen, Convenient for Contrastively Diagnosing Multiply Printing Modes and Formats, Including Manual, Auto 4x3, Auto 3x4+1, Auto 3×4, Auto 2x6+1, Auto 2x6, Auto 3-2+1, Auto 3-2, Auto 1×12+1, Auto 1×12, Rhythm 4, Rhythm 3 And Rhythm 2 etc. Waveform Length Printed can be Adjusted, and with Time Print Function, Which Meets Different Requirements Paper Speed: 5mm/S, 6.25mm/S, 10mm/S, 12.5mm/S, 25mm/S, 50mm/S With the Functions of Auto-Analysis and Auto-Diagnosis for Routine ECG Parameters, Provide Measurement Results and Auto-Diagnosis Conclusion for HR, P-R Interval, P Duration, QRS Duration, T Duration, Q-T Interval, QTc, P Axis, QRS Axis, TAxis, R(V5), S(V1), R(V5) +S(V1) etc. Which Reduces the Doctor''''s Burden Built-in Memory Stores Up To 1000 Cases, Convenient for Case Review and Statistic Multi-Language In Optimal DC State, Up To 10-Hour Standby Time, Continuous Print More Than 3-Hour, Record Up To 300 ECG Waveform (Commonly, it is 3s Case), Which Meets the Requirements of Visiting a Patient at Home and Body ExaminationTechnical Specification • Input Mode: Floating and Defibrillation Protection Frequency Response: 0.05Hz ~ 150Hz(-3dB~+0.4dB) • CMRR: >60dB, >100dB (Add Filter) || Time Constant: ≥ 3.25 Patient Leak Current: <10A | | Calibration Voltage: 1mV Sensitivity: 2.5, 5, 10, 20, 40 mm/mV ‡5%, Standard Sensitivity: 10mm mV2% Noise Level: <15qVp-p|| Input Circuit Current: $50nA Input Impedance: ≥50M | | Sampling Accuracy: 12-bit Safety Classification: Class I, Type CF and Defibrillation-Proof Applied Parts Recording Mode: Thermal Printing System Auto Record: Set Record According to Auto Record Format and Mode, Auto Switching Leads, Measuring and Analysing • Rhythm Record: Set Record According to Rhythm Record Format and Mode, Automatically Measuring and Analysing