AGD Fully Automatic Biochemistry Analyzer Dia Chem 240 plus, Assays: Clinical Chemistry, Centrifugal analyzers
₹5,60,000.00
Specification
- lamp
- Tungsten halogen lamp
- type
- Centrifugal analyzers
- brand
- AGD
- assays
- Clinical Chemistry
- automation
- Fully Automatic
- model name
- AGD 2260
- throughput
- Up to 260 tests per hour
- availability
- In Stock
- power supply
- 240 V ,50-60 Hz
- 9 wavelengths
- 300 to 700nm
- laundry system
- Needles: 8 step washing sequence. Water Consumption: Upto 4 l/ hr
- optical system
- Independent mixing probe
- reaction system
- 90 special cuvettes Length of Cuvette: 6mm Reaction Volume: 200μL to 500μL Reaction Time: 8 to 10 mins Reaction Temperature: 37°C ±0.1°C
- absorbance range
- 0 to 4.00Abs
- reaction cuvette
- Reusable Cuvette
- spectrophotometry
- Rear spectrophotometry
- sample arrangement
- 40 positions for sample, STAT, Calibrator and QC Sample Volume: 2μL to 50μL, step by 0.1μL Compatible with primary collection tube, minimal tube, sample cup, etc.
- reagent arrangement
- 40 reagent positions for R1 and R2 Volume Range: 10μL to 500μL, step by 1μL Reagent Probe: Liquid level detection, collision protection function On board cooling (2°C to 8°C)
- measuring principles
- Absorbance Photometry, Turbidimetry, End-point, Two-point, Kinetic /Dual/ Reagent Chemistry, Monochromatic/ Bichromatic
Add Quantity
Response within 4 hoursTo enquire
Description
Technical Specifications ParameterDescription Throughput Up to 260 tests per hour Measuring Principles Absorbance Photometry, Turbidimetry, End-point, Two-point, Kinetic /Dual/ Reagent Chemistry, Monochromatic/ Bichromatic Sample Arrangement 40 positions for sample, STAT, Calibrator and QC Sample Volume: 2μL to 50μL, step by 0.1μL Compatible with primary collection tube, minimal tube, sample cup, etc. Reagent Arrangement 40 reagent positions for R1 and R2 Volume Range: 10μL to 500μL, step by 1μL Reagent Probe: Liquid level detection, collision protection function On board cooling (2°C to 8°C) Laundry System Needles: 8 step washing sequence. Water Consumption: Upto 4 l/ hr Reaction System 90 special cuvettes Length of Cuvette: 6mm Reaction Volume: 200μL to 500μL Reaction Time: 8 to 10 mins Reaction Temperature: 37°C ±0.1°C Optical System Independent mixing probe 9 wavelengths 300 to 700nm Absorbance range 0 to 4.00Abs Spectrophotometry Rear spectrophotometry Lamp Tungsten halogen lamp * Specifications are subject to change without prior notice.