Crown 400W Digital Cautery Vessel Sealing System And Normal Saline Bipolar Bi-TURP
₹1,79,000
Seller : VD BIO MEDISYSTEMS
Specification
- seal
- Creates vessel fusion with a unique combination of pressure and energy and left no material behind after the process
- brand
- VDBM
- bi cut
- Eliminates excessive current, even during precision cutting in minute tissue structure
- weight
- 7.5Kg (approx)
- bi coag
- For privations of carbonization and highly precise control over coagulation process
- display
- 7segment LED
- voltage
- Input Supply Voltage 230V (+ / - 15%) 50Hz
- category
- surgical vessel sealing cautery
- features
- Vessel fusion with no foreign materialBody and cardiac protected designPatient plate alarm systemHF
- material
- Metal
- warranty
- 1 year
- auto mode
- Initiate coagulation by pressing the foot switch and automatically stops output and audio signal after coagulation
- dimension
- 410mm(L) x 355mm(W) x 155mm(H)
- feature 1
- Vessel fusion with no foreign material
- feature 2
- Body and cardiac protected design
- feature 3
- Patient plate alarm system
- feature 4
- HF leakage current >150mA
- feature 5
- Vessel fusion with permanent fuses
- feature 6
- Involve no dissection & isolation
- feature 7
- Sealing with no sticking or charring
- feature 8
- Does not rely on proximalthrombus
- feature 9
- Feedback-controlled response system
- frequency
- 480khz
- i deal in
- New Only
- mode type
- Cut + coag
- pole type
- Bipolar
- feature 10
- Automatically stops energydelivery as soon as the sealcycle is complete
- feature 11
- Pure cut - A high-frequency alternating current that causes little or no hemostasis with smooth, rapid cuts
- feature 12
- Blend 1 - Offers surgeon varying degrees of hemostasis
- feature 13
- Blend 2 - Vaporization of prostatic tissue or any fat tissue by using higher output wattage
- feature 14
- Endo cut -Automatically regulate cut system for reducing the complication involved in endoscopic sphincterotomy (EST) and serum hyperamylasemia after EST
- feature 15
- Spray - The Coag mode spray output is used for direct coagulation on tissue with spark. The produced spark is not be able to provide any cutting effect with high CREST FACTOR.
- feature 16
- Fulgurate - The sparking in tissue leads towards coagulation. There is no direct contact between tissue and electrode but the voltage is raised to create a spark between the electrodes which in turn coagulate the the tissues in between the process.
- feature 17
- Bipolar :
- feature 18
- Gastric bypass
- feature 19
- Hemorrhoidectomy
- feature 20
- Abdominal hysterectomy
- feature 21
- Adrenalectomy
- feature 22
- Appendectomy
- feature 23
- Colectomy
- feature 24
- Colon resection
- feature 25
- Cystectomy
- feature 26
- Gastrectomy
- feature 27
- Salpingo-oophorectomy
- feature 28
- Vaginal hysterectomy
- feature 29
- Lap-cholecystectomy
- feature 30
- Liver resection
- feature 31
- Nephrectomy
- feature 32
- Nissen fundoplication
- feature 33
- Radical hysterectomy
- feature 34
- Radical prostatectomy
- feature 35
- Splenectomy
- feature 36
- Lap-assisted vaginalhysterectomy (LAVH)
- application
- ENT, General surgery, Gynecology
- foot switch
- Yes
- portability
- Table top
- display type
- 7segment LED
- machine type
- Electrocautery
- output power
- 200 W
- power supply
- 230 V
- product type
- Electrosurgical Generator Electrosurgery Device
- program mode
- 99 User settable program mode
- power control
- Push button
- size dimension
- 410mm(L) x 355mm(W) x 155mm(H)
- country of origin
- Made in India
- model name number
- Crown 400W Digital Cautery Vessel Sealing
- type of equipment
- Surgical Equipment
- usage application
- Hospital
- bipolar coag modes
- Spray,Force,Fulgurate,Dessicate,BI-COAG,BI-CUT,AUTO,SEAL
- operating frequency
- 512KHz
- input supply voltage
- 230V (+ / - 15%) 50Hz
- monopolar coag modes
- (cut & coag) and bipolar
MOQ: 1
Add Quantity
Description
Vessel Sealing System - Monoseal Prime is a forerunner in the field of vessel sealing systems. It presents an improved and safe vessel sealing procedure in the medical sector. Equipped with all safety features like an alarm system and protection from current leakage, this equipment is ideal for minimal access and open surgery.
Features :
Vessel fusion with no foreign material
Body and cardiac protected design
Patient plate alarm system
HF leakage current >150mA
Vessel fusion with permanent fuses
Involve no dissection & isolation
Sealing with no sticking or charring
Does not rely on proximalthrombus
Feedback-controlled response system
Automatically stops energydelivery as soon as the sealcycle is complete
Cut :
Pure cut - A high-frequency alternating current that causes little or no hemostasis with smooth, rapid cuts
Blend 1 - Offers surgeon varying degrees of hemostasis
Blend 2 - Vaporization of prostatic tissue or any fat tissue by using higher output wattage
Endo cut -Automatically regulate cut system for reducing the complication involved in endoscopic sphincterotomy (EST) and serum hyperamylasemia after EST
Coag :
Spray - The Coag mode spray output is used for direct coagulation on tissue with spark. The produced spark is not be able to provide any cutting effect with high CREST FACTOR.
Force - High on the degree of homeostatis the Force mode covers the demands of standard coagulation. The result is the production of fine waveform that creates a resistance in the tissue which in turn results in coagulation, where the hyper evaporation will destroy the tissue. The process provides the ability of the removal of surface structures without causing any damage to deep or peripheral tissues and this also cauterize large surface areas quickly when required.
Fulgurate - The sparking in tissue leads towards coagulation. There is no direct contact between tissue and electrode but the voltage is raised to create a spark between the electrodes which in turn coagulate the the tissues in between the process.
Bipolar :
Bi-coag : For privations of carbonization and highly precise control over coagulation process
Bi-cut : Eliminates excessive current, even during precision cutting in minute tissue structure
Auto mode : Initiate coagulation by pressing the foot switch and automatically stops output and audio signal after coagulation
Seal : Creates vessel fusion with a unique combination of pressure and energy and left no material behind after the process
Specifications :
Program mode : 99 User settable program mode
Frequency : 480khz
Display : 7segment LED
Weight : 7.5Kg (approx)
Dimension : 410mm(L) x 355mm(W) x 155mm(H)
Voltage : Input Supply Voltage 230V (+ / - 15%) 50Hz
Applications :
Gastric bypass
Hemorrhoidectomy
Abdominal hysterectomy
Adrenalectomy
Appendectomy
Colectomy
Colon resection
Cystectomy
Gastrectomy
Salpingo-oophorectomy
Vaginal hysterectomy
Whipple
Lap-cholecystectomy
Liver resection
Nephrectomy
Nissen fundoplication
Radical hysterectomy
Radical prostatectomy
Splenectomy
Lap-assisted vaginalhysterectomy (LAVH)