eB2BMart

Crown 400W Digital Cautery Vessel Sealing System And Normal Saline Bipolar Bi-TURP

₹1,79,000

Seller : VD BIO MEDISYSTEMS

Specification

seal
Creates vessel fusion with a unique combination of pressure and energy and left no material behind after the process
brand
VDBM
bi cut
Eliminates excessive current, even during precision cutting in minute tissue structure
weight
7.5Kg (approx)
bi coag
For privations of carbonization and highly precise control over coagulation process
display
7segment LED
voltage
Input Supply Voltage 230V (+ / - 15%) 50Hz
category
surgical vessel sealing cautery
features
Vessel fusion with no foreign materialBody and cardiac protected designPatient plate alarm systemHF
material
Metal
warranty
1 year
auto mode
Initiate coagulation by pressing the foot switch and automatically stops output and audio signal after coagulation
dimension
410mm(L) x 355mm(W) x 155mm(H)
feature 1
Vessel fusion with no foreign material
feature 2
Body and cardiac protected design
feature 3
Patient plate alarm system
feature 4
HF leakage current >150mA
feature 5
Vessel fusion with permanent fuses
feature 6
Involve no dissection & isolation
feature 7
Sealing with no sticking or charring
feature 8
Does not rely on proximalthrombus
feature 9
Feedback-controlled response system
frequency
480khz
i deal in
New Only
mode type
Cut + coag
pole type
Bipolar
feature 10
Automatically stops energydelivery as soon as the sealcycle is complete
feature 11
Pure cut - A high-frequency alternating current that causes little or no hemostasis with smooth, rapid cuts
feature 12
Blend 1 - Offers surgeon varying degrees of hemostasis
feature 13
Blend 2 - Vaporization of prostatic tissue or any fat tissue by using higher output wattage
feature 14
Endo cut -Automatically regulate cut system for reducing the complication involved in endoscopic sphincterotomy (EST) and serum hyperamylasemia after EST
feature 15
Spray - The Coag mode spray output is used for direct coagulation on tissue with spark. The produced spark is not be able to provide any cutting effect with high CREST FACTOR.
feature 16
Fulgurate - The sparking in tissue leads towards coagulation. There is no direct contact between tissue and electrode but the voltage is raised to create a spark between the electrodes which in turn coagulate the the tissues in between the process.
feature 17
Bipolar :
feature 18
Gastric bypass
feature 19
Hemorrhoidectomy
feature 20
Abdominal hysterectomy
feature 21
Adrenalectomy
feature 22
Appendectomy
feature 23
Colectomy
feature 24
Colon resection
feature 25
Cystectomy
feature 26
Gastrectomy
feature 27
Salpingo-oophorectomy
feature 28
Vaginal hysterectomy
feature 29
Lap-cholecystectomy
feature 30
Liver resection
feature 31
Nephrectomy
feature 32
Nissen fundoplication
feature 33
Radical hysterectomy
feature 34
Radical prostatectomy
feature 35
Splenectomy
feature 36
Lap-assisted vaginalhysterectomy (LAVH)
application
ENT, General surgery, Gynecology
foot switch
Yes
portability
Table top
display type
7segment LED
machine type
Electrocautery
output power
200 W
power supply
230 V
product type
Electrosurgical Generator Electrosurgery Device
program mode
99 User settable program mode
power control
Push button
size dimension
410mm(L) x 355mm(W) x 155mm(H)
country of origin
Made in India
model name number
Crown 400W Digital Cautery Vessel Sealing
type of equipment
Surgical Equipment
usage application
Hospital
bipolar coag modes
Spray,Force,Fulgurate,Dessicate,BI-COAG,BI-CUT,AUTO,SEAL
operating frequency
512KHz
input supply voltage
230V (+ / - 15%) 50Hz
monopolar coag modes
(cut & coag) and bipolar
MOQ: 1
Add Quantity

Send Detailed Enquiry

Your enquiry will be sent to the supplier, for Crown 400W Digital Cautery Vessel Sealing System And Normal Saline Bipolar Bi-TURP.

Qty

Description

Vessel Sealing System - Monoseal Prime is a forerunner in the field of vessel sealing systems. It presents an improved and safe vessel sealing procedure in the medical sector. Equipped with all safety features like an alarm system and protection from current leakage, this equipment is ideal for minimal access and open surgery. Features : Vessel fusion with no foreign material Body and cardiac protected design Patient plate alarm system HF leakage current >150mA Vessel fusion with permanent fuses Involve no dissection & isolation Sealing with no sticking or charring Does not rely on proximalthrombus Feedback-controlled response system Automatically stops energydelivery as soon as the sealcycle is complete Cut : Pure cut - A high-frequency alternating current that causes little or no hemostasis with smooth, rapid cuts Blend 1 - Offers surgeon varying degrees of hemostasis Blend 2 - Vaporization of prostatic tissue or any fat tissue by using higher output wattage Endo cut -Automatically regulate cut system for reducing the complication involved in endoscopic sphincterotomy (EST) and serum hyperamylasemia after EST Coag : Spray - The Coag mode spray output is used for direct coagulation on tissue with spark. The produced spark is not be able to provide any cutting effect with high CREST FACTOR. Force - High on the degree of homeostatis the Force mode covers the demands of standard coagulation. The result is the production of fine waveform that creates a resistance in the tissue which in turn results in coagulation, where the hyper evaporation will destroy the tissue. The process provides the ability of the removal of surface structures without causing any damage to deep or peripheral tissues and this also cauterize large surface areas quickly when required. Fulgurate - The sparking in tissue leads towards coagulation. There is no direct contact between tissue and electrode but the voltage is raised to create a spark between the electrodes which in turn coagulate the the tissues in between the process. Bipolar : Bi-coag : For privations of carbonization and highly precise control over coagulation process Bi-cut : Eliminates excessive current, even during precision cutting in minute tissue structure Auto mode : Initiate coagulation by pressing the foot switch and automatically stops output and audio signal after coagulation Seal : Creates vessel fusion with a unique combination of pressure and energy and left no material behind after the process Specifications : Program mode : 99 User settable program mode Frequency : 480khz Display : 7segment LED Weight : 7.5Kg (approx) Dimension : 410mm(L) x 355mm(W) x 155mm(H) Voltage : Input Supply Voltage 230V (+ / - 15%) 50Hz Applications : Gastric bypass Hemorrhoidectomy Abdominal hysterectomy Adrenalectomy Appendectomy Colectomy Colon resection Cystectomy Gastrectomy Salpingo-oophorectomy Vaginal hysterectomy Whipple Lap-cholecystectomy Liver resection Nephrectomy Nissen fundoplication Radical hysterectomy Radical prostatectomy Splenectomy Lap-assisted vaginalhysterectomy (LAVH)