Contec 6 Channel ECG Machine CMS600G
₹37,500
Seller : VD BIO MEDISYSTEMS
Specification
- cmrr
- >100 dB
- type
- Portable
- brand
- Contec
- weight
- 1.7kg
- warranty
- 1 Year
- lead type
- 12 Lead
- usage type
- Portable ECG
- accessories
- User Manual And Warranty Card, Power Cord, Patient Cable
- paper width
- 110
- sensitivity
- 20
- battery type
- lithium Polymer rechargeable battery
- carry handle
- No
- display type
- Touchscreen LCD
- filters type
- Emg Filter
- machine type
- Digital
- power source
- Rechargeable Battery
- visual alarm
- Yes
- interpretation
- With Interpretation
- operating mode
- Automatic
- packaging type
- Box
- recording type
- Thermal Printing
- digital display
- Yes
- recording speed
- up to 150Hz
- built in printer
- Yes
- recording method
- up to 150H
- country of origin
- Made in India
- digital filtering
- Yes
- iso certification
- Yes
- model name number
- CMS600G
- usage application
- Hospital
- number of channels
- 6 Channels
- safety certificate
- Class I, type CF applied part
- battery backup time
- 90 minutes continuously
- ecg lead annotation
- Yes
- rechargable battery
- Yes
- after sales services
- Yes
- battery operating time
- 4 hours
- standard thermal paper
- Yes
- storage inbuilt memory
- 3GB
- defibrillation protection
- Yes
- diagnostic frequency range
- 0.05Hz ~ 150Hz(-3dB~+0.4dB)
- qwerty alphanumeric keyboard
- Yes
- digital thermal array printer
- Yes
MOQ: 1
Add Quantity
Description
Function 1)Adopt high-resolution thermal printing system(8 dot/mm), no need for any adjustments. Recording frequency: up to 150Hz. 2)Real-time and continuously record the clear and accurate ECG waveform and annotation character(including lead mark, sensitivity, paper speed and filter state, etc.). 3)Full-digital filter design, anti-baseline drift, AC and EMG interference. 4)Adjust the baseline automatically, optimize the print setting and optional rhythm leads. 5)In AUTO mode, finish recording by pressing the button once, which improves work efficiency. 6)Adopt digital signal processing technology and get high-quality ECG waveform via power frequency filter, baseline filter and EMG filter of ECG signal. 7)With the functions of auto-measurement, auto-analysis and auto-diagnosis for routine ECG parameters, which reduces the doctor's burden and improves work efficiency. 8)Sync collection for 12-lead ECG, multiply printing formats, including 2×6+1(rhythm lead), 2×6, 3×4, 3×4+1(rhythm lead), 4×3, 4×3+1(rhythm lead), 6×2, 6×2+1(rhythm lead), rhythm 2, rhythm 3, rhythm 4, rhythm 5, rhythm 6, rhythm 7, channel record, etc. 9)Display of 3/6/12-lead ECG, "Lead off" and "Lack of paper" on one screen, and with ECG DEMO mode. Auto-check and auto-analysis for ECG parameters, ECG waveform can be recorded manually or automatically. And patient information can be stored by case database. 10)Time print can be set to every 1/2/3/5/10/20/30/60 minutes. 11)Print setting, including "Print and save"(print waveform and save case), "Print no save"(only print waveform but not save case), "Save no print"(only save case but not print waveform). 12)AC/DC, built-in rechargeable lithium battery and auto-protection circuit, and automatic power off when there is no operation in appointed time. 13)Store more than 1000 cases, convenient for case review and statistic. 14)Multi-language Performance Input mode floating and defibrillation protection Frequency response 0.05Hz ~ 150Hz(-3dB~+0.4dB) CMRR >60dB, >100dB(add filter) Time constant:≥ 3.2s Patient leak current <10µA Calibration voltage 1mV Sensitivity 2.5, 5, 10, 20, 40 mm/mV ±5%, standard sensitivity: 10mm/mV±2% Noise level <15µVp-p Input circuit current ≤50nA Input impedance ≥50MΩ Sampling accuracy 12-bit Safety classification: class I, type CF and defibrillation-proof applied part Recording mode thermal printing system Auto record set record according to auto record format and mode, automatically switching leads, measuring and analyzing. Rhythm record set record according to rhythm record format and mode, automatically measuring and analyzing. Manual record set record according to record format, manually switching leads. Measurement parameters HR, P-R interval, P Duration, QRS Duration, T Duration, Q-T interval, Q-Tc, P Axis, QRS Axis, T Axis, R(V5), S(V1), R(V5)+S(V1) Paper size 80mm(W)×20m(L) Power frequency filterAC 50Hz/60Hz(-20dB) Sampling frequency 1000Hz EMG interference filter 25Hz/35Hz (-3dB) Paper speed Auto: 5, 6.25, 10, 12.5, 25, 50, 100mm/s, ±5% Rhythm: 5, 6.25, 10, 12.5, 25, 50, 100mm/s, ±5% Manual: 5, 6.25, 10, 12.5, 25, 50, 100mm/s, ±5%