AL4000 Series Hybrid Memory Recorder

₹1,500.00

Specification

weight
About 3.9kg
mounting
Panel mounting
alarm reset
Time, channel No., alarm level
chart speed
1 to 1500mm/h, in 1mm/h increments
availability
In Stock
list printing
When required, interrupt trace printing and print data, chart speed
skip function
No display or printings of channels of which ranges are not set
accuracy rating
+/-0.1% of measuring range +/-1 digit (DC voltage, thermocouple, resistance thermometer inputs)
alarm activated
Time, channel No., alarm type and level
measuring cycle
1 seconds/6-point
memory capacity
Max. 48 data
input resolution
About 1/40,000 or better (converted to reference range)
measuring points
Dot-printing type 6 points
rated power voltage
100 to 240VAC 50/60Hz, universal power supply
ambient humidity range
20 to 80%RH
ambient temperature range
0 to 50 Degree C
maximum power consumption
Max 40VA
common mode rejection ratio
130dB or more (50/60Hz)
maximum common mode voltage
30V AC / 60V DC
normal mode rejection ratio
50dB or more (50/60Hz)
normal operation conditions voltage
90 to 264VAC
normal operation conditions frequency
50/60Hz +/-2%
reference junction compensation accuracy
At ambient temperature 23 to +/-10 Degree C
Add Quantity
Response within 4 hoursTo enquire

Description

Our company has gained name and fame in presenting AL4000 Series Hybrid Memory Recorder.Features:Corresponds to SD cardEquipped with SD card (sold separately) and it can record data, read and write setting value.Full multi rangeEquipped with DC voltage 10 kinds, T/C 36 kinds, RTD 12 kinds, in total 58 kinds. Easily set the range per channelsEasy data management by communication interfaceProvided with USB port and connect with PC directly. RS232C, RS422A, RS485 and Ethernet communication interface is optionally prepared. When Ethernet is selected, settings from the web and E-mail alarm notification are added.Package Software attachedBy Data acquisition software, the use of application expands from recording / management to information processing.*Optional communication interface required.Data analysis software can replay display, wave process, editing and trend display. Parameter setting software can manage the setting information on PC.Standard alarm display / Printing functionSet 4 types of alarm per each input points. When alarm occurs, status display ''ALM'' flashed and measuring value flashes at LCD operation screen.Chart end detection function availableCan set the alarm operation when chart end is detectedVarious programming functionProcess the measured data by programming setting and displayed / recorded data of each channels are shown as programmed result data. Input signals:Thermocouples: B, R, S, K, E, J, T, N, W-WRe26, WRe5-WRe26, PtRh40-PtRh20, NiMo-Ni, CR-AuFe, Platinel II, U, L, Au/PtResistance thermometers: Pt100 (IEC751-1995), Pt100 (IEC751-1983), JPt100,Pt50, Pt-CoDC voltage: ±13.8mV, ±27.6mV, ±69.0mV, ±200mV, ±500mV, ±1V,±5V, ±10V, ±20V, ±50VDC current: Max 50mA by external shunt resistor(100ohms, 250ohms sold separately) Reference junction compensation accuracy:At ambient temperature: 23°C±10°CK, E, J, T, N, Platinel II: ±0.5°Cor EMF 20μV, whichever greaterOther than above: ±1.0°C or EMF 40μV, whichever greater Burnout:Burnout detection function for thermocouple input and RTD input. Upper burnout, lower burnout or burnout disables is selectable for each input Subtract printing:Recording difference between reference channel and measuring value or between reference value (set value) and measuring value