eB2BMart

5 Para Patient Monitor

₹25,000

Seller : VD BIO MEDISYSTEMS

Specification

brand
VD Bio Medisystem
model
VD-9000T
weight
4 KG
mounting
Bedside
condition
New
lead type
5 Lead
parameters
5 Para
usage area
Ward
screen size
12.1 inch
display size
12.1 Inch
monitor type
Cardiac+Multipara
printer type
No Printer
suitable for
Pediatric, Neonatal, Adult
input voltage
220-240 V
battery backup
Up to 2 Hour
operation mode
Touch Display
waveform speed
12.5mm/s, 25mm/s, 50mm/s
type of display
TFT
pulse rate range
20-254bpm
country of origin
Made in India
respiration range
0-120rpm
nibp cuff supplied
Adult
no of leads in ecg
12
type of spo2 probe
Disposable
parameters measured
ECG, RESP, SPO2, NIBP, Temperature
arrhythmia detection
Yes
nibp measurement range
10-270 mmHg
spo2 measurement range
0-100%
temperature probe type
Reusable
spo2 low and high alarm
Yes
mean bp low and high alarm
Yes
nibp measurement technique
Step Deflation Oscillometric
supplied temperature probe
Skin
12 lead interpretation of ecg
Yes
heart rate low and high alarm
Yes
systolic bp low and high alarm
Yes
diastolic bp low and high alarm
Yes
display waveform of respiration
Yes
number of leads analyzed for ecg in single time
5
MOQ: 1
Add Quantity

Send Detailed Enquiry

Your enquiry will be sent to the supplier, for 5 Para Patient Monitor.

Qty

Description

FEATURES · Suitable for adult, pediatric and neonatal patients · 12.1'' TFT color LCD With Touch Screen · Parameters: ECG, NIBP, SpO2, Pulse Rate, Respiration, Temperature and IBP (upgradable) · Maximum 8-channel waveform synchronous display · Graphic and tabular trends for 96 hours for all formats · Multi-screen format · Powerful data management and storage capacity, 500 NIBP measurement data can be storage and recall · AC/DC, built-in rechargeable lithium battery achieves uninterrupted monitoring · Visual and Audio alarms, adjustable. · Measurement Mode: Manual/Auto/Stat SPECIFICATIONS ECG: · 5 lead or 12 lead selectable · Input: 5 lead; RA, LT, RL, LL, V or R, L, N, F, C · Lead selection: I, II, III, aVR, aVL, aVF, Vx, CAL · Gain Selection: ×25, ×0.5, ×1, ×2, auto · Sweep speed: 12.5mm/s, 25mm/s, 50mm/s · Alarm: YES, audible and visual alarm, alarm events recallable. NIBP: · Method: Oscillometry · Mode: Manual/Auto/STAT · Measurement Range: adult 10-270mmHg · Measurement Type: Systolic, Diastolic, Mean · Resolution: 1mmHg · NIBP Accuracy: Mean ±5mmHg, SD ±8mmHg · Alarm: SYS/DIA/MEAN Respiration: · Method: RA-LL impedance · Measurement range: Adult: 0-120rpm, Paediatric/Neonatal: 0-150rpm · Apnea Alarm: YES SpO2: · Measurement range: 0%-100% · Accuracy: ±2% (70%-100%); 0%-69% unspecified. · Alarm range: 0-100% Pulse Rate: · Measurement range: 10 - 270 · Resolution: 1bpm · Accuracy: ±2pm or ±2% Temperature: · Resolution: 0.2 0C · Channel: Dual-channel · Measurement range: 0-50 0C
5 Para Patient Monitor - ₹25,000.00 | VD BIO MEDISYSTEMS | eB2bMart