eB2BMart

VD-9000T Touch Screen Cardiac Monitor

₹25,000

Seller : VD BIO MEDISYSTEMS

Specification

brand
VD Bio Medisystems
model
VD-9000T
weight
3.9 Kg
mounting
Portable, Trolley, Tabletop, Wall Mount, Bedside
condition
New
lead type
5 Lead
parameters
5 Para
usage area
Emergency, ICCU, Ward, ICU
screen size
12.1 inch
connectivity
LAN
display size
12.1" inch Touch Screen
monitor type
Cardiac+Multipara
printer type
No Printer
suitable for
Neonatal, Pediatric, Adult
battery backup
Up to 2 Hour
is it portable
YES
type of display
TFT
pulse rate range
30-250 bpm
respiration range
7-120 Bpm
nibp cuff supplied
Adult
no of leads in ecg
5
type of spo2 probe
Reusable
parameters measured
SPO2, Temperature, RESP, NIBP, ECG
arrhythmia detection
Yes
nibp measurement range
10-270 mmHg
spo2 measurement range
0-100%
temperature probe type
Reusable
type of battery backup
Lithium Ion
mean bp low and high alarm
Yes
nibp measurement technique
Step Deflation Oscillometric
spo2 measurement technique
Nellcor
supplied temperature probe
Skin
12 lead interpretation of ecg
Yes
systolic bp low and high alarm
Yes
diastolic bp low and high alarm
Yes
display waveform of respiration
Yes
number of leads analyzed for ecg in single time
3
MOQ: 1
Add Quantity

Send Detailed Enquiry

Your enquiry will be sent to the supplier, for VD-9000T Touch Screen Cardiac Monitor.

Qty

Description

General Features • 12.1* TFT Colour LCD With Touch Screen • Real Time S-T Segment Analysis and ARR Analysis • Fan Less Design, Quiet, Energy Saving & Clean, Which Reduces Possibility of Cross-Infection • All-Round Monitor for Adult, Pediatric And Neonate • With Standard Interface, Oxygen Graph, Trend Graph, Big Character Interface and View Bed • Large Volume of Tabular and Graphic Trends Information Storage and Easy to Recall • Efficient Resistance to Interference of Defibrillator and HF Knife • Display 7 Lead ECG Waveform in Phase and Capture Dynamic Waveforms • 500 NIBP Measurement Data can be Stored and Recall • Battery Backup: 2 Hours • Dimension: 300 X 270 X 150 mm • Weight: 3 Kg Technical Specification •ECG • 5 Lead: RA, LA, LL, RL, V • Waveform: 3 and 7 Channel Selectable • Heart Rate Range: 15 ~ 300 Bpm • RESP • Method: R-F(RA-LL) Impedance • Measurement Range: 7~120 Bpm • Accuracy: 12 Bpm • Alarm Range: 12mV || Arrhythmia Analysis: YES NIBP • Method: Oscillometry • Measurement Interval in AUTO Mode: 1/2/3/4/5/10/15/30/60/90/120/240/480 Minutes • Measurement Period in STAT Mode: 5 Minutes •Pulse Rate Range: 40 ~ 240 Bpm | | Range: 0 ~ 300 mmHg • Accuracy: $3 mmHg • Accuracy: Maximal-mean Deviation: 15 mmHg || Standard Deviation: 48 mmHg • Over-pressure Protection: Double Salty Protection *Sp02 • Measurement and Alarm Range: 0 ~ 100% • Measurement Accuracy: 70%~ 100% +2% 7 PR • Measurement and Alarm Range: 20 ~ 300 Bpm • Accuracy: $3 Bpm > TEMP • Compatible Probe: YSI or CYF • Dual-channel || Measurement and Alarm Range: 5 ~ 50°C | | Accuracy: ‡0.1°C Optional Configuration: Nellcor Sp0z, 2-IBP, EtCO2, Touch Screen, Central Monitoring Software & Cable (LAN or Wireless) VGA Outpu