VD-9000T Touch Screen Cardiac Monitor
₹25,000
Seller : VD BIO MEDISYSTEMS
Specification
- brand
- VD Bio Medisystems
- model
- VD-9000T
- weight
- 3.9 Kg
- mounting
- Portable, Trolley, Tabletop, Wall Mount, Bedside
- condition
- New
- lead type
- 5 Lead
- parameters
- 5 Para
- usage area
- Emergency, ICCU, Ward, ICU
- screen size
- 12.1 inch
- connectivity
- LAN
- display size
- 12.1" inch Touch Screen
- monitor type
- Cardiac+Multipara
- printer type
- No Printer
- suitable for
- Neonatal, Pediatric, Adult
- battery backup
- Up to 2 Hour
- is it portable
- YES
- type of display
- TFT
- pulse rate range
- 30-250 bpm
- respiration range
- 7-120 Bpm
- nibp cuff supplied
- Adult
- no of leads in ecg
- 5
- type of spo2 probe
- Reusable
- parameters measured
- SPO2, Temperature, RESP, NIBP, ECG
- arrhythmia detection
- Yes
- nibp measurement range
- 10-270 mmHg
- spo2 measurement range
- 0-100%
- temperature probe type
- Reusable
- type of battery backup
- Lithium Ion
- mean bp low and high alarm
- Yes
- nibp measurement technique
- Step Deflation Oscillometric
- spo2 measurement technique
- Nellcor
- supplied temperature probe
- Skin
- 12 lead interpretation of ecg
- Yes
- systolic bp low and high alarm
- Yes
- diastolic bp low and high alarm
- Yes
- display waveform of respiration
- Yes
- number of leads analyzed for ecg in single time
- 3
MOQ: 1
Add Quantity
Description
General Features • 12.1* TFT Colour LCD With Touch Screen • Real Time S-T Segment Analysis and ARR Analysis • Fan Less Design, Quiet, Energy Saving & Clean, Which Reduces Possibility of Cross-Infection • All-Round Monitor for Adult, Pediatric And Neonate • With Standard Interface, Oxygen Graph, Trend Graph, Big Character Interface and View Bed • Large Volume of Tabular and Graphic Trends Information Storage and Easy to Recall • Efficient Resistance to Interference of Defibrillator and HF Knife • Display 7 Lead ECG Waveform in Phase and Capture Dynamic Waveforms • 500 NIBP Measurement Data can be Stored and Recall • Battery Backup: 2 Hours • Dimension: 300 X 270 X 150 mm • Weight: 3 Kg Technical Specification •ECG • 5 Lead: RA, LA, LL, RL, V • Waveform: 3 and 7 Channel Selectable • Heart Rate Range: 15 ~ 300 Bpm • RESP • Method: R-F(RA-LL) Impedance • Measurement Range: 7~120 Bpm • Accuracy: 12 Bpm • Alarm Range: 12mV || Arrhythmia Analysis: YES NIBP • Method: Oscillometry • Measurement Interval in AUTO Mode: 1/2/3/4/5/10/15/30/60/90/120/240/480 Minutes • Measurement Period in STAT Mode: 5 Minutes •Pulse Rate Range: 40 ~ 240 Bpm | | Range: 0 ~ 300 mmHg • Accuracy: $3 mmHg • Accuracy: Maximal-mean Deviation: 15 mmHg || Standard Deviation: 48 mmHg • Over-pressure Protection: Double Salty Protection *Sp02 • Measurement and Alarm Range: 0 ~ 100% • Measurement Accuracy: 70%~ 100% +2% 7 PR • Measurement and Alarm Range: 20 ~ 300 Bpm • Accuracy: $3 Bpm > TEMP • Compatible Probe: YSI or CYF • Dual-channel || Measurement and Alarm Range: 5 ~ 50°C | | Accuracy: ‡0.1°C Optional Configuration: Nellcor Sp0z, 2-IBP, EtCO2, Touch Screen, Central Monitoring Software & Cable (LAN or Wireless) VGA Outpu