CMS5100 Contec Table Top Pulse Oximeter

₹13,000

Seller : VD BIO MEDISYSTEMS

Specification

type
Handheld
brand
CONTEC
model
CMS5100
phase
Single Phase
weight
1.5 kg
features
Portable
mounting
Tabletop
usb port
Yes
warranty
1 Year
wireless
Yes
parameters
SpO2+Pulse
probe type
Reusable
usage type
Home Use, Hospital Use, Ambulance Use, Clinic Use
power suppl
rated voltage: ~220 V, rated power: 50 Hz
safety type
Class I equipment, type BF defibrillation-proof applied part
sp o2 range
0% to 100%
battery type
Li-polymer battery
display size
2.8"
display type
Dual Color LED
power source
Rechargeable Battery
suitable for
Neonatal, Pediatric, Adult
amc extension
Yes
ethernet port
Yes
input voltage
220-240 V
oximeter type
Table Top
type of alarm
Visual
battery backup
Up to 2 Hour
type of display
TFT
pulse rate range
30-250 bpm
respiration range
0 BPM - 120 BPM
screen resolution
1mmHg
cuff leakage alarm
Yes
nibp cuff supplied
Adult
parameter measures
SpO2 + Pulse Rate + NIBP
pr measuring range
25-260mmHg.
type of spo2 probe
Reusable
parameter displayed
SpO2 & Pulse
parameters measured
Temperature, PR, SPO2
suspension of alarm
Yes
arrhythmia detection
No
battery working hour
2-3 hours
cuff disconnect alarm
Yes
nibp measurement range
25-260mmHg
spo2 measurement range
0-100%
temperature probe type
Reusable
type of battery backup
Lithium Ion
adjustable alarm volume
Yes
spo2 low and high alarm
Yes
wall mount availability
Yes
mean bp low and high alarm
Yes
nibp measurement technique
Step Deflation Oscillometric
supplied temperature probe
Skin
12 lead interpretation of ecg
No
heart rate low and high alarm
Yes
low battery voltage indication
Yes
systolic bp low and high alarm
Yes
temperature low and high alarm
Yes
diastolic bp low and high alarm
Yes
display waveform of respiration
Yes
inbuilt thermal recorder printer
No
respiratory rate low and high alarm
Yes
sensor wire probe disconnection alarm
Yes
central patient monitoring station connectivity
No
MOQ: 1
Add Quantity
Piece

Send Detailed Enquiry

Your enquiry will be sent to the supplier, for CMS5100 Contec Table Top Pulse Oximeter.

Qty

Description

Introduction CMS5100 Patient Monitor is a feature-rich monitoring device that can be applied to adults, pediatric and neonate. User can choose different measurement parameters according to different needs. The patient monitor can monitor NIBP, SpO2 and PR. It integrates the function of parameter measuring and displaying into a compact, lightweight patient monitor, which is suitable for all levels of hospitals, community medical and home use. Features 1)Be applicable for NIBP and SpO2 monitoring of adult, pediatric and neonate of all ages, easy to operate, high cost-effective; 2)Be applicable for medicine, surgery, operating room, ICU/CCU, emergency room, obstetrics and gynecology, pediatrics; 3)Compact and flexible appearance, easy for carrying and suitable for indoor and outdoor (in ambulance) monitoring; 4)Built-in rechargeable lithium polymer battery, ensuring uninterrupted monitoring; 5)Perfect menu design, user-friendly interface; 6)Display the measurement result of SYS, DIA, MAP, SpO2, PR and bar graph by the display screen of high-brightness digital tube; 7)2.8'''' (320×240) true color TFT LCD screen, displays the information of time, SpO2 Plethysmogram, alarm condition, trend graph, list and system settings, etc.; 8)Visual and audible alarm for SYS, DIA, MAP, SpO2 and PR, and upper and lower limit of alarm can be set as necessary; 9)Independent nonvolatile memory, storage for up to 2,000 groups of NIBP data and 78,000 groups of SpO2 data; 10)Convenient and quick in reviewing measurement data, available for reviewing the NIBP trend graph of 24 hours and SpO2 trend graph of 22 hours. Performance 1 NIBP Using Oscillometry technology, also called Oscillography technology to measure the blood pressure. 1)Measurement mode: manual/auto/continuous 2)Measurement interval in auto mode: 1, 2, 3, 4, 5, 5×n(n=2, 3, 4...51) min. 3)Resolution: 1 mmHg 4)Accuracy: max mean error: ±5 mmHg; max standard deviation: 8 mmHg. 5)Overpressure protection: dual protection for both software and hardware 6)Others: reset, self-testing and accuracy testing of static pressure 7)Measurement range: Adult SYS 40 mmHg~270 mmHg MAP 20 mmHg~235 mmHg DIA 10 mmHg~215 mmHg Pediatric: SYS 40 mmHg~200 mmHg MAP 20 mmHg~165 mmHg DIA 10 mmHg~150 mmHg Neonate: SYS 40 mmHg~135 mmHg MAP 20 mmHg~110 mmHg DIA 10 mmHg~100 mmHg 2 SpO2 Using Photoelectric Oxyhemoglobin Inspection Technology combined with Capacity Pulse Scanning & Recording Technology to measure the saturation of blood oxygen.1)Measurement range: 0 %~100 % 2)Alarm range: 0 %~100 % 3)Resolution: 1 % 4)Accuracy: 70 %~100 %, ±2 %; below 70 % unspecified. 3 PR Using Photoelectric Oxyhemoglobin Inspection Technology combined with Capacity Pulse Scanning & Recording Technology to measure the pulse rate. 1)Measurement range: 25 bpm~250 bpm 2)Alarm range: 25 bpm~250 bpm 3)Resolution: 1 bpm 4)Accuracy: ±2 bpm or ±2 %, whichever is greater 4 Safety and Power supply 1)Power supply: rated voltage: ~220 V, rated power: 50 Hz 2)Safety classification: Class I equipment, type BF defibrillation-proof applied part