CMS5100 Contec Table Top Pulse Oximeter
₹13,000
Seller : VD BIO MEDISYSTEMS
Specification
- type
- Handheld
- brand
- CONTEC
- model
- CMS5100
- phase
- Single Phase
- weight
- 1.5 kg
- features
- Portable
- mounting
- Tabletop
- usb port
- Yes
- warranty
- 1 Year
- wireless
- Yes
- parameters
- SpO2+Pulse
- probe type
- Reusable
- usage type
- Home Use, Hospital Use, Ambulance Use, Clinic Use
- power suppl
- rated voltage: ~220 V, rated power: 50 Hz
- safety type
- Class I equipment, type BF defibrillation-proof applied part
- sp o2 range
- 0% to 100%
- battery type
- Li-polymer battery
- display size
- 2.8"
- display type
- Dual Color LED
- power source
- Rechargeable Battery
- suitable for
- Neonatal, Pediatric, Adult
- amc extension
- Yes
- ethernet port
- Yes
- input voltage
- 220-240 V
- oximeter type
- Table Top
- type of alarm
- Visual
- battery backup
- Up to 2 Hour
- type of display
- TFT
- pulse rate range
- 30-250 bpm
- respiration range
- 0 BPM - 120 BPM
- screen resolution
- 1mmHg
- cuff leakage alarm
- Yes
- nibp cuff supplied
- Adult
- parameter measures
- SpO2 + Pulse Rate + NIBP
- pr measuring range
- 25-260mmHg.
- type of spo2 probe
- Reusable
- parameter displayed
- SpO2 & Pulse
- parameters measured
- Temperature, PR, SPO2
- suspension of alarm
- Yes
- arrhythmia detection
- No
- battery working hour
- 2-3 hours
- cuff disconnect alarm
- Yes
- nibp measurement range
- 25-260mmHg
- spo2 measurement range
- 0-100%
- temperature probe type
- Reusable
- type of battery backup
- Lithium Ion
- adjustable alarm volume
- Yes
- spo2 low and high alarm
- Yes
- wall mount availability
- Yes
- mean bp low and high alarm
- Yes
- nibp measurement technique
- Step Deflation Oscillometric
- supplied temperature probe
- Skin
- 12 lead interpretation of ecg
- No
- heart rate low and high alarm
- Yes
- low battery voltage indication
- Yes
- systolic bp low and high alarm
- Yes
- temperature low and high alarm
- Yes
- diastolic bp low and high alarm
- Yes
- display waveform of respiration
- Yes
- inbuilt thermal recorder printer
- No
- respiratory rate low and high alarm
- Yes
- sensor wire probe disconnection alarm
- Yes
- central patient monitoring station connectivity
- No
MOQ: 1
Add Quantity
Piece
Description
Introduction CMS5100 Patient Monitor is a feature-rich monitoring device that can be applied to adults, pediatric and neonate. User can choose different measurement parameters according to different needs. The patient monitor can monitor NIBP, SpO2 and PR. It integrates the function of parameter measuring and displaying into a compact, lightweight patient monitor, which is suitable for all levels of hospitals, community medical and home use. Features 1)Be applicable for NIBP and SpO2 monitoring of adult, pediatric and neonate of all ages, easy to operate, high cost-effective; 2)Be applicable for medicine, surgery, operating room, ICU/CCU, emergency room, obstetrics and gynecology, pediatrics; 3)Compact and flexible appearance, easy for carrying and suitable for indoor and outdoor (in ambulance) monitoring; 4)Built-in rechargeable lithium polymer battery, ensuring uninterrupted monitoring; 5)Perfect menu design, user-friendly interface; 6)Display the measurement result of SYS, DIA, MAP, SpO2, PR and bar graph by the display screen of high-brightness digital tube; 7)2.8'''' (320×240) true color TFT LCD screen, displays the information of time, SpO2 Plethysmogram, alarm condition, trend graph, list and system settings, etc.; 8)Visual and audible alarm for SYS, DIA, MAP, SpO2 and PR, and upper and lower limit of alarm can be set as necessary; 9)Independent nonvolatile memory, storage for up to 2,000 groups of NIBP data and 78,000 groups of SpO2 data; 10)Convenient and quick in reviewing measurement data, available for reviewing the NIBP trend graph of 24 hours and SpO2 trend graph of 22 hours. Performance 1 NIBP Using Oscillometry technology, also called Oscillography technology to measure the blood pressure. 1)Measurement mode: manual/auto/continuous 2)Measurement interval in auto mode: 1, 2, 3, 4, 5, 5×n(n=2, 3, 4...51) min. 3)Resolution: 1 mmHg 4)Accuracy: max mean error: ±5 mmHg; max standard deviation: 8 mmHg. 5)Overpressure protection: dual protection for both software and hardware 6)Others: reset, self-testing and accuracy testing of static pressure 7)Measurement range: Adult SYS 40 mmHg~270 mmHg MAP 20 mmHg~235 mmHg DIA 10 mmHg~215 mmHg Pediatric: SYS 40 mmHg~200 mmHg MAP 20 mmHg~165 mmHg DIA 10 mmHg~150 mmHg Neonate: SYS 40 mmHg~135 mmHg MAP 20 mmHg~110 mmHg DIA 10 mmHg~100 mmHg 2 SpO2 Using Photoelectric Oxyhemoglobin Inspection Technology combined with Capacity Pulse Scanning & Recording Technology to measure the saturation of blood oxygen.1)Measurement range: 0 %~100 % 2)Alarm range: 0 %~100 % 3)Resolution: 1 % 4)Accuracy: 70 %~100 %, ±2 %; below 70 % unspecified. 3 PR Using Photoelectric Oxyhemoglobin Inspection Technology combined with Capacity Pulse Scanning & Recording Technology to measure the pulse rate. 1)Measurement range: 25 bpm~250 bpm 2)Alarm range: 25 bpm~250 bpm 3)Resolution: 1 bpm 4)Accuracy: ±2 bpm or ±2 %, whichever is greater 4 Safety and Power supply 1)Power supply: rated voltage: ~220 V, rated power: 50 Hz 2)Safety classification: Class I equipment, type BF defibrillation-proof applied part