Contec Cms 70a Tabletop Pulse Oximeter

₹14,000

Seller : VD BIO MEDISYSTEMS

Specification

type
Tabletop
voltage
AC 100~240V, 50/60HZ
accuracy
± 2bpm or ± 2% (select larger)
features
Memory, Rechargeable, Alarm, PI Indicator, Neonatal Mode
warranty
1 Year
feature 1
Low power consumption
feature 2
SpO2 value display
feature 3
Pulse rate value display, bar graph display
feature 4
PI display
feature 5
Pulse waveform display
feature 6
Menu operation
feature 7
Screen brightness can be changed
feature 8
The display mode can be changed
feature 9
Pulse rate sound indication can be turned on or turned off
feature 10
With measured data overruns, limits and low-voltage alarm function, the upper/down alarm range can be adjustable
feature 11
Connected with an external oximeter probe
feature 12
Data storage function, and the storage data can be uploaded to a computer
feature 13
Real-time data can be transmitted to computers
usage type
Hospital Use, Ambulance Use, ICU Use
power suppl
About 350mA
safety type
II device, BF Type
sp o2 range
0% to 100%
battery type
built-in rechargeable Li-Polymer battery
display mode
TFT Screen and LED display
display type
LED
power source
Rechargeable Battery
power supply
Built-in recharge Li-Polymer
suitable for
All Age Groups
oximeter type
Table Top
country of origin
Made in India
power consumption
About 350mA
screen resolution
320*240
pr measuring range
30bpm~250bpm(the resolution is 1bpm)
parameter displayed
SpO2 & Pulse
battery working hour
After the device built-in battry finished the charge, it's continuous working time is not less than 1 hour
sp o2 measuring range
0%~100%(the resolution is 1%)
resistance to surrounding light
The deviation between the value measured in the condition of man-made light or indoor natural light and that of darkroom is less than ± 1%.
measurement performance in weak filling condition
SpO2 and pulse rate can be shown correctly when pulse-filling ratio is 0.4%. SpO2 error is ± 4%, pulse rate error is ± 2 bpm or ± 2% (select larger).
battery capacity indication low voltage indication
low-voltage indicator appears before working abnormally which is due to low-voltage and with alarm function
Add Quantity
Piece

Send Detailed Enquiry

Your enquiry will be sent to the supplier, for Contec Cms 70a Tabletop Pulse Oximeter.

Qty

Description

Specifications: Display Mode: TFT Screen and LED display Screen Resolution: 320*240 SpO2 Measuring Range: 0%~100%(the resolution is 1%) Accuracy: 70%~100%: ± 2%, Below 70% unspecified. PR Measuring Range: 30bpm~250bpm(the resolution is 1bpm) Accuracy: ± 2bpm or ± 2% (select larger) Measurement Performance in Weak Filling Condition: SpO2 and pulse rate can be shown correctly when pulse-filling ratio is 0.4%. SpO2 error is ± 4%, pulse rate error is ± 2 bpm or ± 2% (select larger). Resistance to surrounding light: The deviation between the value measured in the condition of man-made light or indoor natural light and that of darkroom is less than ± 1%. Power Consumption: About 350mA Voltage: AC 100~240V, 50/60HZ Power Supply: Built-in recharge Li-Polymer Battery working hour: After the device built-in battry finished the charge, it's continuous working time is not less than 1 hour Safety Type: II device, BF Type Contec CMS70A Portable Tabletop Pulse Oximeter Features: Low power consumption SpO2 value display Pulse rate value display, bar graph display PI display Pulse waveform display Menu operation Screen brightness can be changed The display mode can be changed Pulse rate sound indication can be turned on or turned off With measured data overruns, limits and low-voltage alarm function, the upper/down alarm range can be adjustable Battery capacity indication, Low-voltage indication: low-voltage indicator appears before working abnormally which is due to low-voltage and with alarm function Connected with an external oximeter probe Data storage function, and the storage data can be uploaded to a computer Real-time data can be transmitted to computers Additional information Warranty 1 year