Contec Cms 70a Tabletop Pulse Oximeter
₹14,000
Seller : VD BIO MEDISYSTEMS
Specification
- type
- Tabletop
- voltage
- AC 100~240V, 50/60HZ
- accuracy
- ± 2bpm or ± 2% (select larger)
- features
- Memory, Rechargeable, Alarm, PI Indicator, Neonatal Mode
- warranty
- 1 Year
- feature 1
- Low power consumption
- feature 2
- SpO2 value display
- feature 3
- Pulse rate value display, bar graph display
- feature 4
- PI display
- feature 5
- Pulse waveform display
- feature 6
- Menu operation
- feature 7
- Screen brightness can be changed
- feature 8
- The display mode can be changed
- feature 9
- Pulse rate sound indication can be turned on or turned off
- feature 10
- With measured data overruns, limits and low-voltage alarm function, the upper/down alarm range can be adjustable
- feature 11
- Connected with an external oximeter probe
- feature 12
- Data storage function, and the storage data can be uploaded to a computer
- feature 13
- Real-time data can be transmitted to computers
- usage type
- Hospital Use, Ambulance Use, ICU Use
- power suppl
- About 350mA
- safety type
- II device, BF Type
- sp o2 range
- 0% to 100%
- battery type
- built-in rechargeable Li-Polymer battery
- display mode
- TFT Screen and LED display
- display type
- LED
- power source
- Rechargeable Battery
- power supply
- Built-in recharge Li-Polymer
- suitable for
- All Age Groups
- oximeter type
- Table Top
- country of origin
- Made in India
- power consumption
- About 350mA
- screen resolution
- 320*240
- pr measuring range
- 30bpm~250bpm(the resolution is 1bpm)
- parameter displayed
- SpO2 & Pulse
- battery working hour
- After the device built-in battry finished the charge, it's continuous working time is not less than 1 hour
- sp o2 measuring range
- 0%~100%(the resolution is 1%)
- resistance to surrounding light
- The deviation between the value measured in the condition of man-made light or indoor natural light and that of darkroom is less than ± 1%.
- measurement performance in weak filling condition
- SpO2 and pulse rate can be shown correctly when pulse-filling ratio is 0.4%. SpO2 error is ± 4%, pulse rate error is ± 2 bpm or ± 2% (select larger).
- battery capacity indication low voltage indication
- low-voltage indicator appears before working abnormally which is due to low-voltage and with alarm function
Add Quantity
Piece
Description
Specifications:
Display Mode: TFT Screen and LED display
Screen Resolution: 320*240
SpO2 Measuring Range: 0%~100%(the resolution is 1%)
Accuracy: 70%~100%: ± 2%, Below 70% unspecified.
PR Measuring Range: 30bpm~250bpm(the resolution is 1bpm)
Accuracy: ± 2bpm or ± 2% (select larger)
Measurement Performance in Weak Filling Condition: SpO2 and pulse rate can be shown correctly when pulse-filling ratio is 0.4%. SpO2 error is ± 4%, pulse rate error is ± 2 bpm or ± 2% (select larger).
Resistance to surrounding light: The deviation between the value measured in the condition of man-made light or indoor natural light and that of darkroom is less than ± 1%.
Power Consumption: About 350mA
Voltage: AC 100~240V, 50/60HZ
Power Supply: Built-in recharge Li-Polymer
Battery working hour: After the device built-in battry finished the charge, it's continuous working time is not less than 1 hour
Safety Type: II device, BF Type
Contec CMS70A Portable Tabletop Pulse Oximeter Features:
Low power consumption
SpO2 value display
Pulse rate value display, bar graph display
PI display
Pulse waveform display
Menu operation
Screen brightness can be changed
The display mode can be changed
Pulse rate sound indication can be turned on or turned off
With measured data overruns, limits and low-voltage alarm function, the upper/down alarm range can be adjustable
Battery capacity indication, Low-voltage indication: low-voltage indicator appears before working abnormally which is due to low-voltage and with alarm function
Connected with an external oximeter probe
Data storage function, and the storage data can be uploaded to a computer
Real-time data can be transmitted to computers
Additional information
Warranty
1 year