eB2BMart

Syringe Infusion Pump Byond Byz810

₹20,000

Seller : VD BIO MEDISYSTEMS

Specification

mode
Rate Mode
type
Syringe Pump
alarm
YES
brand
Byond
weight
2.2kg
accuracy
high accuracy
mounting
Pole Mount
dimension
280X210X130 mm
kvo speed
1ml/h ~ 5 ml/h (1ml/h step)
bolus rate
50/60ml Syringe: 1,200ml/h 30 ml Syringe: 720ml/h 20 ml Syringe: 480ml/h 10 ml Syringe: 240ml/h
purge rate
100ml/h ~ 1,000ml/h
battery type
AC/DC and built-in lithium battery
channel type
Single Channel
display type
LCD
power source
AC 100V ~ 240V, 50/60Hz
power supply
AC 110/230 V
syringe size
10ML TO 60 ML
volume limit
1ml ~ 9999ml
certification
CE,ISO13485
infusion mode
Dose Mode, Time Mode, Rate Mode
battery backup
Battery Capacity 1,600mAh, 4 Hours Interna
flow rate range
0.1 to 1500 ml/hr
occlusion level
High
total injection
0.1ml ~ 9999.9ml
country of origin
China
power consumption
30 VA
usage application
Hospital
number of syringes
1
MOQ: 1
Add Quantity

Send Detailed Enquiry

Your enquiry will be sent to the supplier, for Syringe Infusion Pump Byond Byz810.

Qty

Description

General Features HD LCD Display, High-Capacity Words, Friendly User Interface, Dynamically Display Working Status V Audible and Visual Alarm for Occlusion, Empty, Near Empty, Low Battery, End of Infusion, Syringe Loose, Wrong Setting, etc. Compatible With 5ml, 10ml, 20ml, 30ml, 50/60mL Syringe of any Brands Pre-set Solution Volume to Greatly Reduce the Workload of Nurses Three Working Modes: Rate Mode, Time Volume Mode, Dosage Weight Mode Three Levels of Occlusion: High, Medium and Low v Purge and Bolus Function v KVO (Keep-Vein-Open) Automatically Opens as Injection is Completed, KVO Rate is 0.1-5mL/h (0.1mL/h Step) Freely Stackable: Freely Stack One Syringe Pump onto Another to Provide Multiple Solutions, Which Have a Wide Range of Clinical Applications Power Source: AC100 ~ 240V 50/60Hz; Internal Battery, DC12V Car Charge One-Key Operation Makes Setup Easy and Simple Syringe Plunger Grabble Detector, Operatable with One Hand in a No-Germ Environment Automatically Record the Settings of Last InjectionTechnical Specification • Unique Human Voice Alarm System: The Device Triggered the Human Voice Prompt and Stop Injection Automatically When There is any Malfunction, Making the Infusion Process Safer and More Reliable Rate: 50/60ml Syringe: 0.1mL/h ~ 999.9mL/h (0.1mL/h Step) 1,000mL/h ~ 1,500mL/h (1mL/h Step) 30mL Syringe: 0.1mL/h ~ 900.0mL/h (0.1mL/h Step) 20ml Syringe: 0.1mL/h ~ 600.0mL/h (0.1mL/h Step) 10ml Syringe: 0.1mL/h ~ 300.0mL/h (0.1mL/h Step) • • • Flow Rate Accuracy: Within ‡3% (After Correct Calibration) Mechanical Precision: Within ‡2% Bolus Rate: 50/60 mL Syringe: 1,200mL/h 30 mL Syringe: 720mL/h 20 mL Syringe: 480mL/h 10 mL Syringe: 240mL/h • Purge Rate: 50/60ml Syringe: 1,500mL/h 30 ml Syringe: 900mL/h 20 mL Syringe: 600mL/h 10 mL Syringe: 300mL/h • • • Volume Limit: 0.1mL ~ 9999.9mL (0.1mL Step) Total Injection Volume: 0.1mL ~ 9999.9mL (0.1mL Step) Occlusion of Single Channel Syringe Pump: High: 800mmHg t 200mmHg (106.7kPa ‡ 26.7kPa) Medium: 50/600mmHg ‡ 100mmg (66.7kPa t 13.3kPa) Low: 300mmg + 100mmHg (40.7kPa ‡ 13.3kPa) • Alarms: Injection Soon Finishes, End of Injection, Occlusion, Improperly Installation of Syringe, Wrong Setting, Low Battery, Syringe Loose etc. • Power Source: AC 100V ~ 240V 50/60Hz, Internal Rechargeable Lithium Battery Capacity ≥ 1,600mAh, 4 Hours Internal Battery Backup • • • KVO Rate: 1mL/h Fuse: F1AL/250/60V, 2 Pcs Inside Power Consumption: 30VA IP Classification: IPX4 • Equipment Classification: Class II, Internal Power Supply, Type CF Applied Parts Operating Condition Ambient temperature: +5°C~ +40°C • • • • • Relative Humidity: 20 ~ 90% Transport & Storage Condition: Ambient temperature: -30°C~ +55°C Relative Humidity: ≤ 95% Dimension: 280mm (L) x 210mm(W) × 130mm(H) Weight: 2.2kg (Net Weight)