eB2BMart

Horizontal Autoclave Stainless Steel Hospital Autocalve, 6 - 18 KW

₹3,00,000.00

Specification

type
Horizontal Autoclave
brand
Reico
shape
Horizontal
usage
Hospital
material
Stainless Steel
availability
In Stock
chamber volume
75 - 2000 Liters
material grade
SS 304
insulation wall
Triple Wall
automation grade
Fully Automatic
power consumption
6 - 18 KW
temperature range
121 -134 Degree Celsius
pressure range psi
17-33
Add Quantity
Response within 4 hoursTo enquire

Description

Product Details: Door: Single door with Radial locking system Mode of control: With a multiport valve / Automatic Optional Door: SS Door Wing Nut/ Radial Locking Pre-vacuum and post vacuum: To eliminate air packs and ensure effective sterilization. Water protection: In the event of low water the supply to the heaters is discontinued automatically and visually indicated in the control panel. Pressure switch: An automatic pressure switch adjustable type is provided to set the required pressure. Vacuum drying: An effective vacuum drying is caused with powerful ejector and vacuum breaker which draws air from the atmosphere. It is filtered, pre-heated(sterilized) and finally enters the working chamber for effective drying. Water Gauge glass: To note down the level of water glass tube with gauge is provided. Gasket: Silicon Expansion type Instrumentation: Safety Valve Vacuum Breaker Non-Return Valve Steam Trap Water Inlet And Water Outlet Valves The sequence of Automatic operation includes the following: Automatic water filling for the steam generator Leak test for required time and results with alarm will be displayed and data logged. Bowie-did test Spore-test results from approved lab submitted Pulsing ( vacuuming, purging and pre-heating)_ Optional Sterilization with temp and balance time displayed and data logged Exhaustion appropriate to liquid, instruments and fabric cycles. Drying cycle with the vacuum pump. – Optional Final cooling with admission of filtered air (0.2 Micron) Sterilization completes with F.O values Displayed and data's logged Optional: High Vacuum with vacuum pump Fully Automatic Micro processor or PLC based programmable with solenoid valve operation. Suitable for Liquid, Instruments and Fabric cycle Data Loging System Double Door System Pulsing Controller Model CHAMBER Dia Volume Voltage Power Dimension Door (mm) X Deep (mm) Ltr Kw W x L x HT mm Lock HC1624 400 X 600 75 440 6 650x850x1600 Single Point HC1644 400 X 1100 138 440 9 650x1350x1600 Single HC2036 500 X 900 176 440 9 950x1500x1900 Radial HC2044 500 X 1100 216 440 9 950x1700x1900 Radial HC2048 500 x 1200 235 440 9 950 x1800x1900 Radial HC2436 600 X 900 254 440 12 1050x1500x1900 Radial HC3048 750 X 1200 520 440 18 1200x1800x1900 Radial

Verify supplier credentials before transacting. Enquiries create leads for the supplier.